Only one configuration may have thisīy default, user configuration one is loaded at boot. Sets the delay until the system forces a power off after ignitionįalls or the system voltage drops below a safe level.Įxample: set hard-off-timer 150 set boot-config Description:ĭetermines which user configuration is loaded when the system isįirst connected to AC power. The system voltage drops below the safe level.Įxample: set shutdown-timer 20 set hard-off-timer Description: Sets the delay before the system powers off after ignition falls or When disabled, the host will assume that allĮxample: set hotplug on set shutdown-timer Description:

com5 putty download

Required to be an int (12, 19) on the K300.įloating point shutdown voltages will be added to the K300 asĮxample: set shutdown-voltage 12 set hotplug Description:Įnables or disables display port hotplug detection.ĭisabling hotplug detection will keep displays from re-arranging if a On the K700 this value may be a float (12.5, 19.2) but is

com5 putty download

Parameters: volts -> The low voltage shutdown level: 0 - Max System Voltage (V) Setting this voltage to a value of '6' or less disables the feature. Will turn off the input voltage drops below this level for more than Parameters: time -> Time delay in seconds: 0 - 9999 (s)Įxample: set startup-timer 15 set shutdown-voltage Description:ĭesigned to protect automotive systems from battery drain, the system Sets the delay before the system powers on after detecting ignition. Parameters: enable -> Enable or disable: 'on' or 'off'Įxample: set ignition-sense off set startup-timer Description: Therefore, after the hard-off timer has expired, This is achieved by emulating a front power button press, and can be The ignition pin goes high, and power off if the pin falls for more They include: set ignition-sense Description:Įnables or disables ignition sensing. Several configuration parameters may also be set. Parameters: config-number -> The configuration number: 1 - 4 Sets the currently active user configuration. This is a required step or any changes will revert after reboot. Parameters: - Example: config save-config Description: Reports the current microcontroller configuration settings. The available commands for controlling system configurations include: config Description: The active configuration may be cycled by pressing the settings switch. This allows for temporarily disabling automotive features, like low voltage shutdown. The system can store up to four different configurations, one of which will be loaded as default when the system is first powered on. These primarily include automotive features, like ignition sensing and battery drain protection.

Com5 putty download series#

The Karbon series has several configuration options that effect system behavior.

Com5 putty download serial#

Parameters: - Example: get-voltage Serial Commands – System Configuration This command is currently only available on the K700. Reports the current system input voltage.

com5 putty download

Parameters: - Example: status get-voltage Description: Reports the firmware version number and system dependent status Parameters: - Example: version status Description:

com5 putty download

Reports the firmware version number and build date. The available information is system dependent, and is not unified across all Karbon systems.Ĭommands for reporting this information include: version Description: For instance, the K700 can report the current system input voltage, internal temperature, and internal humidity. This covers firmware version and build date, alongside physical and electrical status information. The serial terminal can report various system information to the host. Serial Commands Serial Commands – System Information

Com5 putty download update#

This utility may also be used to update the microcontroller’s firmware version.

Com5 putty download download#

Reporting the firmware version from windows or linuxĬomplete instructions on using the utility are included as part of the download package. You can download the utility for Windows or Linux systems here, and use it to communicate directly with the onboard MCU. The Karbon command line utility is a straightforward method for managing all core microcontroller functionality. Note: We recommend making sure your microcontroller firmware is up to date before trying any of the below. It also provides a complete list of the exact command strings supported by the microcontroller. This article will outline several methods for interfacing with the system’s MCU. This microcontroller can be managed by sending commands to two virtual serial ports from the operating system. Karbon K300 and K700 series computers have an internal microcontroller (MCU) that manages features like DIO, CAN, Ignition sensing, and more.